Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
1.
Dental press j. orthod. (Impr.) ; 26(2): e211945, 2021. tab, graf
Artigo em Inglês | LILACS, BBO | ID: biblio-1249705

RESUMO

ABSTRACT Objective: This paper aims to verify the thermodynamic, mechanical and chemical properties of CuNiTi 35ºC commercial wires. Methods: Forty pre-contoured copper-nickel-titanium thermodynamic 0.017 x 0.025-in archwires with an Af temperature of 35°C were used. Eight wires from five different manufacturers (American Orthodontics® [G1], Eurodonto® [G2], Morelli® [G3], Ormco® [G4] and Orthometric® [G5]) underwent cross-sectional dimension measurements, tensile tests, SEM-EDS and differential scanning calorimetry (DSC) tests. Parametric tests (One-way ANOVA and Tukey post-test) were used, with a significance level of 5%, and Pearson's correlation coefficient test was performed between the Af and chemical elements of the wires. All sample tests and statistical analyses were double-blinded. Results: All wires presented standard dimensions (0.017 x 0.025-in) and superelastic behavior, with mean plateau forces of: G1 = 36.49N; G2 = 27.34N; G3 = 19.24 N; G4 = 37.54 N; and G5 = 17.87N. The Af means were: G1 = 29.40°C, G2 = 29.13°C and G3 = 31.43°C, with p>0.05 relative to each other. G4 (32.77°C) and G5 (35.17°C) presented statistically significant differences between each other and among the other groups. All samples presented Ni, Ti, Cu and Al in different concentrations. Conclusions: The chemical concentration of the elements that compose the alloy significantly influenced the thermodynamic and mechanical properties.


RESUMO Objetivo: O presente artigo teve como objetivo verificar as propriedades termodinâmicas, mecânicas e químicas de fios CuNiTi 35°C comerciais. Métodos: Foram utilizados 40 arcos termodinâmicos pré-contornados de cobre-níquel-titânio de 0,017" x 0,025" e temperatura Af de 35°C. Oito fios de cinco fabricantes diferentes (American Orthodontics® [G1], Eurodonto® [G2], Morelli® [G3], Ormco® [G4] e Orthometric® [G5]) foram submetidos a medições de suas secções transversais, testes de tração, MEV-EDS e calorimetria diferencial (DSC). Foram utilizados testes paramétricos (One-way ANOVA e pós-teste de Tukey), com nível de significância de 5%, e foi realizado o teste do coeficiente de correlação de Pearson entre a temperatura Af e os elementos químicos dos fios. Todos os testes das amostras e análises estatísticas foram duplo-cegos. Resultados: Todos os fios apresentavam dimensões padronizadas (0,017" x 0,025") e comportamento superelástico, com forças médias de platô de G1 = 36,49 N; G2 = 27,34 N; G3 = 19,24 N; G4 = 37,54 N; e G5 = 17,87 N. As médias de Af foram: G1 = 29,40°C, G2 = 29,13°C e G3 = 31,43°C, com p> 0,05 entre si. G4 (32,77°C) e G5 (35,17°C) apresentaram diferenças estatisticamente significativas entre si e entre os demais grupos. Todas as amostras apresentaram Ni, Ti, Cu e Al em diferentes concentrações. Conclusões: A concentração química dos elementos que compõem a liga influenciou significativamente as propriedades termodinâmicas e mecânicas.


Assuntos
Fios Ortodônticos , Ligas Dentárias , Estresse Mecânico , Titânio , Teste de Materiais , Estudos Transversais , Elasticidade
2.
Dental press j. orthod. (Impr.) ; 22(6): 61-67, Nov.-Dec. 2017. tab, graf
Artigo em Inglês | LILACS | ID: biblio-891107

RESUMO

ABSTRACT Objective: Evaluate changes in the force system of T-Loop Springs (TLS) preactivated by curvature, due to stress relaxation. Methods: Ninety TLSs measuring 6 x 10 mm, produced out with 0.017 x 0.025-in TMA® wire and preactived by gradual curvature, were randomly distributed into nine groups according to time point of evaluation. Group 1 was tested immediately after spring preactivation and stress relief, by trial activation. The other eight groups were tested after 24, 48 and 72 hours, 1, 2, 4, 8 and 12 weeks, respectively. Using a moment transducer coupled to a digital extensometer indicator adapted to a universal testing machine, the amount of horizontal force, moment and moment-to-force ratios were recorded at every 0.5 mm of deactivation from 5 mm of the initial activation, in an interbracket distance of 23 mm. Results: The horizontal forces decreased gradually among the groups (p< 0.001) and the moments showed a significant and slow decrease over time among the groups (p< 0.001). All groups produced similar M/F ratios (p= 0.532), with no influence of time. Conclusions: The TLSs preactivated by curvature suffered a gradual deformation over time, which affected the force system, specifically the moments, which affected the horizontal forces produced.


RESUMO Objetivo: avaliar as mudanças no sistema de forças das molas T pré-ativadas por curvatura, devido ao alívio de tensão estrutural. Métodos: noventa molas em forma de "T", medindo 6 mm x 10 mm, confeccionadas com fio de beta-titânio TMA® de 0,017" x 0,025" e pré-ativadas por curvatura gradual, foram distribuídas aleatoriamente em nove grupos, de acordo com o momento de avaliação. O Grupo 1 foi testado imediatamente após a pré-ativação da mola e liberação do estresse, por meio de simulação da ativação. Os outros oito grupos foram divididos conforme o intervalo de tempo testado: após 24, 48 e 72 horas; 1, 2, 4, 8 e 12 semanas. Usando um transdutor de momentos acoplado a um indicador digital para extensometria e adaptado a uma máquina universal de ensaios, as magnitudes da força horizontal, do momento e da proporção momento/força (M/F) foram registradas a cada 0,5 mm de desativação a partir da ativação inicial de 5 mm, utilizando-se uma distância interbraquetes de 23 mm. Resultados: as forças horizontais reduziram-se gradualmente nos grupos (p< 0,001) e o momento apresentou uma queda lenta e significativa ao longo do tempo (p< 0,001). Todos os grupos tiveram proporções M/F semelhantes (p= 0,532), não influenciadas pelo período de tempo. Conclusões: as molas pré-ativadas por curvatura gradual sofreram deformação progressiva ao longo do tempo, o que afetou o sistema de forças - especificamente o momento -, alterando as forças horizontais produzidas.


Assuntos
Fios Ortodônticos , Titânio/química , Desenho de Aparelho Ortodôntico , Fechamento de Espaço Ortodôntico/instrumentação , Ligas Dentárias/química , Análise do Estresse Dentário , Estresse Mecânico , Fatores de Tempo , Fenômenos Biomecânicos , Teste de Materiais , Distribuição Aleatória , Estatísticas não Paramétricas
3.
Dental press j. orthod. (Impr.) ; 22(2): 118-125, Mar.-Apr. 2017. graf
Artigo em Inglês | LILACS | ID: biblio-840218

RESUMO

ABSTRACT Even though few technological advancements have occurred in Orthodontics recently, the search for more efficient treatments continues. This paper analyses how to accelerate and improve one of the most arduous phases of orthodontic treatment, i.e., correction of the curve of Spee. The leveling of a deep curve of Spee can happen simultaneously with the alignment phase through a method called Early Vertical Correction (EVC). This technique uses two cantilevers affixed to the initial flexible archwire. This paper describes the force system produced by EVC and how to control its side effects. The EVC can reduce treatment time in malocclusions with deep curves of Spee, by combining two phases of the therapy, which clinicians ordinarily pursue sequentially.


RESUMO Apesar de haver poucos desenvolvimentos tecnológicos nos últimos anos dentro da Ortodontia, a busca por tratamentos mais eficientes não cessou. Assim, o presente artigo visa analisar, de maneira lógica, como otimizar uma das fases do tratamento ortodôntico que mais demandam tempo: a correção da sobremordida exagerada. Pretende-se demonstrar como realizá-la concomitantemente ao alinhamento inicial, por meio de uma técnica denominada correção vertical precoce (CVP). Essa técnica utiliza dois cantilevers associados ao primeiro fio de alinhamento ortodôntico, mas não restritos a ele, a fim de iniciar a planificação da curva de Spee o mais cedo possível. Assim, o tempo de tratamento pode ser diminuído, já que duas fases do tratamento, normalmente realizadas de forma independente, podem ser realizadas ao mesmo tempo. Além disso, tanto o sistema de forças quanto os efeitos colaterais e os passos da execução da técnica serão devidamente apresentados e discutidos.


Assuntos
Humanos , Fios Ortodônticos , Ortodontia Corretiva/métodos , Má Oclusão Classe II de Angle/terapia , Mandíbula/patologia , Ortodontia Corretiva/instrumentação , Recidiva , Fatores de Tempo , Dimensão Vertical , Fenômenos Biomecânicos , Resultado do Tratamento , Braquetes Ortodônticos , Arco Dental/anatomia & histologia , Arco Dental/diagnóstico por imagem , Oclusão Dentária , Sobremordida/patologia , Sobremordida/terapia , Má Oclusão Classe II de Angle/diagnóstico por imagem
4.
Dental press j. orthod. (Impr.) ; 22(1): 38-46, Jan.-Feb. 2017. tab, graf
Artigo em Inglês | LILACS | ID: biblio-840214

RESUMO

ABSTRACT Objective: The aim of this paper was to determine the amount of deformation in four commercial brands of nickel-titanium closed springs. Methods: A total of 130 springs were divided into 13 subgroups, according to their features and manufacturers (Morelli, Orthometric, Ormco and GAC) and activated from 100% to 1000% of the effective length of the nickel-titanium portion present at the spring, at 37 °C. Deactivation data were plotted and deformation was found graphically. The values were compared by analysis of variance and Tukey's post-hoc test. Results: Springs manufactured by Morelli had the same amount of deformation when they were activated up to 700% of Y activation; springs by Orthometric had the same amount of deformation up to 600-700% of Y; springs by Ormco had the same amount of deformation up to 700-800% of Y; and finally, the majority of springs by GAC had similar deformation up to 800%-1000% of activation. All springs tested could be activated up to 700% without rupture. Conclusions: Most subgroups were similarly deformed up to 700% of activation, without rupture of springs. Subgroups 4B, 4C, 4D and 4E showed the same amount of deformation up to 1000% of activation without any rupture at all.


RESUMO Objetivo: o objetivo desse trabalho foi determinar a deformação em molas fechadas de níquel-titânio de quatro marcas comerciais. Métodos: cento e trinta molas foram divididas em treze subgrupos, de acordo com suas características e fabricantes (Morelli, Orthometric, Ormco e GAC), com ativação entre 100% e 1.000% do comprimento efetivo de níquel-titânio presente na mola (Y), a 37 °C. Dados de desativação foram coletados e a deformação foi obtida de forma gráfica. Os valores foram comparados por meio de análise de variância e teste post-hoc de Tukey. Resultados: as molas da Morelli apresentaram a mesma quantidade de deformação considerando-se 700% de ativação de Y; as molas da Orthometric tiveram a mesma quantidade de deformação até 600-700% de Y; as molas da Ormco tiveram a mesma quantidade de deformação até 700-800% de Y; e, por fim, a maioria das molas da GAC apresentou deformação semelhante até 800-1.000% de ativação. Todas as molas testadas puderam ser ativadas até 700% sem ruptura. Conclusões: a maioria dos subgrupos se deformou de maneira semelhante até 700% de ativação, sem ruptura das molas. Os subgrupos 4B, 4C, 4D e 4E demonstraram a mesma quantidade de deformação até 1.000% de ativação, sem nenhuma ruptura.


Assuntos
Aparelhos Ortodônticos , Titânio , Análise do Estresse Dentário , Níquel , Teste de Materiais , Desenho de Aparelho Ortodôntico , Elasticidade , Ligas
5.
Dental press j. orthod. (Impr.) ; 21(4): 114-125, July-Aug. 2016. graf
Artigo em Inglês | LILACS | ID: lil-795067

RESUMO

ABSTRACT Introduction: A reasonable exposure of incisors and gingival tissues is generally considered more attractive than excess or lack of exposure. A reasonable gingival exposure is considered to be around 0 to 2 mm when smiling and 2-4 mm exposure of the maxillary incisor edge when the lips are at rest. Objective: The aim of this paper is to present the Functional Aesthetic Occlusal Plane (FAOP), which aims to help in the diagnosis of the relationships established among molars, incisors and the upper lip. Conclusion: FAOP can complement an existing and established orthodontic treatment plan, facilitating the visualization of functional and aesthetic demands by giving a greater focus on the position of incisors in the relationship established among the incisors, molars and the upper lip stomion.


RESUMO Introdução: uma exposição razoável dos incisivos e da gengiva é, geralmente, considerada mais atraente do que quando há excesso ou falta de exposição, tanto de dentes quanto de gengiva. Essa faixa razoável encontra-se em torno de 0 a 2mm de exposição gengival durante o sorriso e de 2 a 4mm de exposição da borda incisal dos incisivos superiores em repouso. Objetivo: o objetivo do presente trabalho é apresentar o plano oclusal estético funcional (POEF), que tem por propósito auxiliar no diagnóstico da relação de posicionamento entre molares, incisivos e ponto estômio do lábio superior. Conclusão: o POEF pode ser um complemento ao plano de tratamento ortodôntico já existente e estabelecido, facilitando a visualização das demandas estéticas e funcionais, dando um enfoque maior à posição dos incisivos na relação entre os incisivos, molares e o ponto estômio do lábio superior.


Assuntos
Humanos , Ortodontia Corretiva , Planejamento de Assistência ao Paciente , Oclusão Dentária , Estética Dentária , Sorriso , Lábio/anatomia & histologia
6.
Dental press j. orthod. (Impr.) ; 21(3): 46-55, tab, graf
Artigo em Inglês | LILACS | ID: lil-787911

RESUMO

abstract Objective: This paper analyzed whether nickel-titanium closed coil springs (NTCCS) have a different superelastic (SE) behavior according to activation and whether their force plateau corresponds to that informed by the manufacturer. Methods: A total of 160 springs were divided into 16 subgroups according to their features and activated proportionally to the length of the extensible part (NiTi) of the spring (Y). The force values measured were analyzed to determine SE rates and force plateaus, which were mathematically calculated. These plateaus were compared to those informed by the manufacturer. Analysis of variance was accomplished followed by Tukey post-hoc test to detect and analyze differences between groups. Results: All subgroups were SE at the activation of 400% of Y length, except for: subgroups 4B and 3A, which were SE at 300%; subgroups 4E and 4G, which were SE at 500%; and subgroup 3C, which was SE at 600%. Subgroup 3B did not show a SE behavior. Force plateaus depended on activation and, in some subgroups and some activations, were similar to the force informed. Conclusions: Most of the springs showed SE behavior at 400% of activation. Force plateaus are difficult to compare due to lack of information provided by manufacturers.


resumo Objetivo: o presente artigo analisou se as molas helicoidais fechadas de níquel-titânio apresentam superelasticidade (SE), de acordo com a ativação, e se o platô de força medido corresponde ao informado pelo fabricante. Material e Métodos: 160 molas foram divididas em 16 subgrupos, de acordo com suas características, e foram ativadas proporcionalmente ao comprimento da parte extensível (NiTi) da mola (Y). Os valores de força obtidos foram analisados para determinar as taxas de SE e os platôs de força, os quais foram calculados matematicamente - sendo esses platôs comparados aos informados pelos fabricantes. Uma análise de variância foi realizada, seguida do teste post-hoc de Tukey, para detectar e analisar as diferenças entre os grupos. Resultados: todos os subgrupos apresentaram SE em ativação de 400% do comprimento Y, com exceção dos subgrupos 4B e 3A (que apresentaram SE a 300%), dos subgrupos 4E e 4G (com SE a 500%) e do subgrupo 3C (que apresentou SE na ativação de 600%). O subgrupo 3B não apresentou comportamento superelástico. Os platôs de força dependeram da ativação e em alguns subgrupos, em determinadas ativações, foram semelhantes à força informada pelo fabricante. Conclusões: a maioria das molas apresentou comportamento superelástico na ativação de 400%. Os platôs de força são difíceis de ser comparados, devido à falta de informações por parte dos fabricantes.


Assuntos
Humanos , Fios Ortodônticos , Titânio , Ligas Dentárias , Análise do Estresse Dentário , Níquel , Estresse Mecânico , Teste de Materiais , Desenho de Aparelho Ortodôntico , Elasticidade
7.
Ortodontia ; 49(4): 339-343, jul./ago. 2016. ilus
Artigo em Português | LILACS, BBO | ID: biblio-875223

RESUMO

O desejo de ter um tratamento ortodôntico mais rápido é comum a pacientes e profissionais, e muitos meios para acelerar o movimento dentário têm sido pesquisado em todo o mundo. Um dos recursos mais publicitados, se fundamenta na aplicação de estímulos vibratórios nos dentes para induzir uma resposta biológica mais rápida. Desta forma, este artigo objetivou discutir, através de revisão crítica da literatura atual se há segurança na aplicação deste estímulo na clínica diária.


The desire to have a short-term orthodontic treatment is common to both patients and orthodontists and many ways to accelerate tooth movement has been researched around the world. One of the most publicized ways is based on the application of vibratory stimuli to the teeth to induce faster biological response. The authors conducted a critical review of the current literature aiming to clarify whether is safety in the application of this stimulus in everyday practice.


Assuntos
Técnicas de Movimentação Dentária/tendências , Ortodontia Corretiva , Vibração/uso terapêutico
8.
Dental press j. orthod. (Impr.) ; 20(6): 89-96, Nov.-Dec. 2015. tab, graf
Artigo em Inglês | LILACS | ID: lil-770272

RESUMO

Abstract Objective: Evaluation of the force system produced by four brands of b-Ti wires bent into an elaborate design. Methods: A total of 40 T-loop springs (TLS) hand-bent from 0.017 x 0.025-in b-Ti were randomly divided into four groups according to wire brand: TMATM(G1), BETA FLEXYTM (G2), BETA III WIRETM (G3) and BETA CNATM (G4). Forces and moments were recorded by a moment transducer, coupled to a digital extensometer indicator adapted to a testing machine, every 0.5 mm of deactivation from 5 mm of the initial activation. The moment-to-force (MF) ratio, the overlapping of the vertical extensions of the TLSs and the load-deflection (LD) ratio were also calculated. To complement the results, the Young's module (YM) of each wire was determined by the slope of the load-deflection graph of a tensile test. The surface chemical composition was also evaluated by an energy dispersive X-ray fluorescence spectrometer. Results: All groups, except for G2, produced similar force levels initially. G3 produced the highest LD rates and G1 and G4 had similar amounts of overlap of the vertical extensions of the TLSs in "neutral position". G1 and G3 delivered the highest levels of moments, and G2 and G3 produced the highest MF ratios. b-Ti wires from G3 produced the highest YM and all groups showed similar composition, except for G2. Conclusion: The four beta-titanium wires analyzed produced different force systems when used in a more elaborate design due to the fact that each wire responds differently to bends.


Resumo Objetivo: avaliar os sistemas de força produzidos por quatro marcas de fios de -Ti, dobrados em formas complexas. Métodos: quarenta molas T-Loop (TLS) dobradas à mão, confeccionadas a partir de fios de -Ti, calibre 0,017" x 0,025", foram aleatoriamente divididas em quatro grupos, de acordo com a marca do fio: TMA (G1), BETA FLEXY (G2), BETA III Wire (G3) e BETA CNA (G4). Forças e momentos foram registrados por um transdutor de momento - acoplado a um extensômetro digital, adaptado a uma máquina de ensaios -, a cada 0,5mm de desativação, a partir de 5mm da ativação inicial. A proporção momento-força (M/F), a sobreposição das extensões verticais das TLSs e a relação carga-deflexão (C/D) também foram calculadas. Para completar os resultados, o módulo de Young (MY) de cada fio foi determinado pelo declive no gráfico de carga-deflexão em um ensaio de tração. Ademais, a composição química da superfície foi avaliada por um espectrômetro de fluorescência de raios X por energia dispersiva. Resultados: todos os grupos, exceto o G2, produziram níveis de força semelhantes, inicialmente. O G3 produziu as maiores taxas de C/D, enquanto G1 e G4 tiveram quantidades similares de sobreposição das extensões verticais das TLSs em posição neutra. G1 e G3 geraram os mais altos níveis de momentos, enquanto G2 e G3 produziram os mais altos índices de M/F. Os fios -Ti do G3 produziram o maior MY, e todos os grupos apresentaram composição semelhante, exceto G2. Conclusão: os quatro fios de beta-titânio analisados produziram diferentes sistemas de forças, quando utilizados para formas mais complexas, devido ao fato de que cada fio responde de forma diversa à confecção de dobras.


Assuntos
Estresse Mecânico , Fios Ortodônticos , Titânio , Teste de Materiais , Ligas Dentárias
9.
Rev. Clín. Ortod. Dent. Press ; 13(6): 10-15, dez.-jan. 2015. ilus
Artigo em Português | LILACS, BBO | ID: biblio-856022

RESUMO

É impressionante como os fabricantes fazem alegações sem confirmação aparente sobre a validação ou veracidade de suas declarações, ao mesmo tempo que lutamos por apoio à pesquisa científica.


Assuntos
Braquetes Ortodônticos/normas , Ortodontia Corretiva/métodos , Fenômenos Biomecânicos
10.
Rev. Clín. Ortod. Dent. Press ; 13(5): 19-25, out.-nov. 2014. ilus
Artigo em Português | LILACS, BBO | ID: biblio-856020

RESUMO

Os dentes mais difíceis de serem corrigidos, quando mal posicionados, são os segundos molares. Seu mau posicionamento, espontâneo ou causado, pode gerar contatos prematuros que atrapalham a eficiência do tratamento. Esse problema pode ocorre nos três planos do espaço (eixo x, y e z) e, às vezes é tão difícil de ser resolvidos que muitos clínicos evitam incluir os segundos molares no aparelho ortodôntico. Por que isso ocorre?


Assuntos
Dente Pré-Molar , Fenômenos Biomecânicos , Ortodontia
11.
Rev. Clín. Ortod. Dent. Press ; 13(3): 38-43, jun.-jul. 2014. ilus
Artigo em Português | LILACS, BBO | ID: biblio-855990

RESUMO

Um dos aspectos mecânicos ortodônticos que parece ser mais mal compreendido nos dias de hoje, em todo mundo, é o atrito...


Assuntos
Fenômenos Biomecânicos/fisiologia , Ortodontia , Atrito Dentário
12.
Ortodontia ; 45(1): 25-32, jan.-fev. 2012. ilus, tab, graf
Artigo em Português | LILACS, BBO | ID: lil-713851

RESUMO

Esta pesquisa avaliou in vitro a resistência ao cisalhamentode bráquetes ortodônticos fotopolimerizados com o arco de plasma, odiodo emissor de luz (LED) e a luz halógena convencional em diferentestempos. Bráquetes foram colados em 60 pré-molares superioreshumanos, divididos em cinco grupos. Nos grupos 1 e 2 utilizou-se a luzarco de plasma por três e seis segundos, respectivamente; nos grupos3 e 4 utilizou-se o LED por cinco e dez segundos, respectivamente; nogrupo 5 utilizou-se a luz halógena por 40 segundos. Os corpos de provaforam armazenados em água destilada em temperatura ambiente e,após 24 horas dos procedimentos de colagem, foram submetidos aosensaios mecânicos na máquina universal MTS-Material Test System. Paraa complementação dos resultados, também foi realizada a avaliação e aclassificação do padrão de descolagem dos bráquetes utilizando o lAR.Os resultados foram analisados por meio da análise de variância (Anova,seguida do teste SNK de Tukey para comparação múltipla de médias.Nãohouve diferenças entre os grupos 2, 4 e 5, as quais foram maioresque as médias dos grupos 1 e 3, iguais entre si. Os escores do lAR nãomostraram diferenças quanto à interface de descolagem entre os trêstipos de luz em todos os tempos testados. A luz arco de plasma e o LEDpodem ser utilizados por tempos reduzidos, dentro de certos limites,em relação à luz halógena na colagem de bráquetes ortodônticos, semperda de resistência ao cisalhamento.


This study evaluated in vitro the shear bond strength ofbraekets bonded with xenon plasma are light, light-emitting diode (LED)and conventional halogen light using different curing times. Bracketswere bonded to the bueeal surfaee of 60 human maxillary premolarsalloeated to tive groups. In groups 1 and 2, the resin was cured with theplasma are for three and six seconds (5), respectively; in groups 3 and4, the LED was used for tive and ten 5, respectively; and in group 5, thehalogen light was used for 40 s. The specimens were stored in waterfor 24 hours and subjected to a shear force until bracket failure. Thedebonding pattern was classified according to the adhesive remnant index(ARI). The results were assessed by Anova and the SNK post-hoe test.No differenees were deteeted among groups 2, 4 and 5, whieh showedhigher averages than groups 1 and 3, whieh were not different betweenthemselves. The ARI scores showed no differenees among the three typesof light sourees in ali times tested. Plasma are and LED lights ean be usedwith shorter euring times, within certain limits, than conventional halogenlight for bonding orthodontie brackets, without decreasing bond strength.


Assuntos
Lâmpadas de Polimerização Dentária , Cura Luminosa de Adesivos Dentários , Lasers Semicondutores , Braquetes Ortodônticos , Resistência ao Cisalhamento , Dente Pré-Molar , Fototerapia
13.
Rev. Clín. Ortod. Dent. Press ; 10(2): 24-27, abr.-maio 2011. ilus, tab
Artigo em Português | LILACS, BBO | ID: biblio-855851

RESUMO

O desgaste interproximal no esmalte dentário constitui um procedimento comum na prática ortodôntica. O protocolo de execução deve ser preciso e muito bem planejado para evitar desgaste em excesso ou sensibilidade tardia na região. O objetivo do presente trabalho foi descrever passo a passo o desgaste interproximal, assim como mostrar os acessórios utilizados e a sua execução clínica em dentes posteriores.


Assuntos
Humanos , Masculino , Adulto , Protocolos Clínicos , Esmalte Dentário , Má Oclusão , Desgaste dos Dentes
14.
Ortho Sci., Orthod. sci. pract ; 1(2): 195-199, 2008. ilus
Artigo em Português | LILACS, BBO | ID: lil-544314

RESUMO

Contenções linguais fixas são utilizadas comumente na ortodontia após a remoção de aparelhos fixos. Devido aos seus tamanhos, formatos e à anatomia da face lingual dos dentes ântero-inferiores, existem algumas dificuldades em manter a contenção em seu lugar durante o procedimento de colagem. Essas dificuldades podem comprometer o correto posicionamento da contenção e a sua aderência aos dentes. A inabilidade de conseguir-se manter a contenção em seu devido lugar durante a sua colagem pode aumentar o tempo de cadeira e comprometer a estabilidade da contenção. Significância: Se houver uma maneira confiável, simples e rápida de se manter a contenção em posição, o clínico poderia fixá-la mais rapidamente e mais consistentemente. O propósito neste artigo é apresentada uma maneira simples e confiável de se colar contenções linguais.


Assuntos
Humanos , Contenções Ortodônticas , Fios Ortodônticos
15.
Araraquara; s.n; dez. 2007. 96 p. ilus, tab.
Tese em Português | LILACS, BBO | ID: lil-510695

RESUMO

Objetivo: Avaliar a retração parcial de caninos utilizando a mola “T” (TTLS) do grupo A a e a perda de ancoragem dos molares, analisar mecanicamente a mesma TTLS e também avaliar a pré-ativação da TTLS do grupo B, por curvatura e dobras. Material e Método: Quatro artigos científicos foram redigidos e utilizados para a avaliação dos propósitos apresentados. Resultados: Os caninos superiores foram retraídos 3,2 mm, enquanto os inferiores foram retraídos 4,1 mm. Os molares superiores e inferiores foram protraídos 1,0 mm e 1,2 mm, respectivamente. Os caninos se movimentam 1,5 mm no primeiro mês e 2,43 mm no segundo. A TTLS do grupo A deve ter 7 X 10 mm, e ao ser ativada 4 mm, ficar posicionada a 2 mm do bráquete anterior e ter a dobra de gable a 4 mm do tubo posterior. A pré-ativação da TTLS do grupo B por curvatura gerou M/F em média 2,5 mm maiores que a pré-ativação por dobras. Conclusões: Os caninos superiores foram retraídos por inclinação controlada, enquanto os inferiores foram retraídos por inclinação descontrolada. Os molares superiores e inferiores foram protraídos por inclinação controlada. Em 2,1 meses de retração de 14 caninos, a perda de ancoragem dos molares foi de 0,3 :1. Os caninos se movimentam mais no segundo mês do que no primeiro. Foi possível desenvolver uma padronização e otimização da TTLS pré-ativada para o grupo A. A pré-ativação da TTLS do grupo B por curvatura gerou M/F maiores quando comparada a pré-ativação por dobras.


Assuntos
Fenômenos Biomecânicos , Técnicas de Movimentação Dentária , Ortodontia Corretiva
16.
Araraquara; s.n; 2007. 97 p. ilus.
Tese em Português | LILACS, BBO | ID: lil-590766

RESUMO

Objetivo: Avaliar a retração parcial de caninos utilizando a mola “T” (TTLS) do grupo A a e a perda de ancoragem dos molares, analisar mecanicamente a mesma TTLS e também avaliar a pré-ativação da TTLS do grupo B, por curvatura e dobras. Material e Método: Quatro artigos científicos foram redigidos e utilizados para a avaliação dos propósitos apresentados. Resultados: Os caninos superiores foram retraídos 3,2 mm, enquanto os inferiores foram retraídos 4,1 mm. Os molares superiores e inferiores foram protraídos 1,0 mm e 1,2 mm, respectivamente. Os caninos se movimentam 1,5 mm no primeiro mês e 2,43 mm no segundo. A TTLS do grupo A deve ter 7 X 10 mm, e ao ser ativada 4 mm, ficar posicionada a 2 mm do bráquete anterior e ter a dobra de gable a 4 mm do tubo posterior. A pré-ativação da TTLS do grupo B por curvatura gerou M/F em média 2,5 mm maiores que a pré-ativação por dobras. Conclusões: Os caninos superiores foram retraídos por inclinação controlada, enquanto os inferiores foram retraídos por inclinação descontrolada. Os molares superiores e inferiores foram protraídos por inclinação controlada. Em 2,1 meses de retração de 14 caninos, a perda de ancoragem dos molares foi de 0,3 :1. Os caninos se movimentam mais no segundo mês do que no primeiro. Foi possível desenvolver uma padronização e otimização da TTLS pré-ativada para o grupo A. A pré-ativação da TTLS do grupo B por curvatura gerou M/F maiores quando comparada a pré-ativação por dobras.


Objective: To evaluate both the partial retraction of canines and the loss of anchorage of the molars using a Group A Titanium “T” Loop Spring (TTLS), and also to evaluate the preactivation differences of curvature vs. bends on a group B TTSL. Materials and Method: Four research papers were written and analyzed for the evaluation of the aims presented. Results: Upper canines were retracted 3.2 mm, while the lower ones were retracted 4.1 mm. The upper and lower molars were protracted 1.0 and 1.2 mm, respectively. The canines were moved 1.5 mm in the first month and 2.43 mm on the second, on average. The group A TTLS should have 7 X 10 mm, and on 4 mm of activation, it should be located 2 mm from the anterior bracket with its preactivation bend positioned 4 mm from the posterior tube. The group B TTLS preactivated by curvature generated M/F ratios 2.5mm larger than the bend preactivation, on average. Conclusions: The upper canines were retracted by controlled tipping, while the lower ones were retracted by uncontrolled tipping. The upper and lower molars were protracted by controlled tipping. In 2.1 months of canine retraction, the loss of anchorage was 0.3:1, compared to the canines. The canines were moved more in the first month than on the 16 second. It was possible to develop a standard and an optimization for the group A TTLS. The Group B TTLS preactivated by curvature generated larger M/F when compared to the bend preactivation.


Assuntos
Fenômenos Biomecânicos , Técnicas de Movimentação Dentária , Ortodontia
17.
J. bras. ortodon. ortop. facial ; 10(58): 409-419, jul.-ago. 2005. ilus, tab
Artigo em Português | LILACS, BBO | ID: lil-502330

RESUMO

A estabilidade da oclusão dentária é um tema bastante polêmico na comunidade ortodôntica, por isso vem sendo estudada incessantemente ao longo dos anos. Desse modo, é importante que os paciente sejam informados quanto ao risco da recidiva e limitações do tratamento antes de iniciá-lo e conscientizá-los de que utilizarão a contenção por um longo período, com monitoração contínua durante a vida adulta. O objetivo desse estudo foi avaliar a opinião de vários autores baseada na revisão de literatura e apresentar casos, mostrando que é possível estabelecer estabilidade; desde que o diagnóstico e o plano de tratamento sejam realizados de modo criterioso, com a utilização de uma técnica dominada pelo profissional e também com a colaboração do paciente.


Assuntos
Humanos , Masculino , Adolescente , Oclusão Dentária , Diagnóstico Bucal/métodos , Contenções Ortodônticas , Ajuste Oclusal , Responsabilidade Técnica , Suspensão de Tratamento
18.
J. bras. ortodon. ortop. facial ; 10(55): 22-27, jan.-fev. 2005. ilus
Artigo em Português | LILACS, BBO | ID: lil-495659

RESUMO

A classe II é uma má olusão comumente observada na clínica ortodôntica e apresenta inúmeras opções de tratamentos que incluem a ortopedia funcional dos maxilares e aparelhos extrabucais, entre outros. De acordo com o diagnóstico, em relação à localização do problema, maxila ou mandíbula, é determinado o tipo de aparatologia mais adequado para cada caso. O objetivo deste artigo é descrever o caso de um paciente com Classe II, divisão 1, apresentando protrusão maxilar. Ele foi tratado com sucesso utilizando-se o aparelho AEB-removível.


Assuntos
Humanos , Masculino , Criança , Aparelhos de Tração Extrabucal , Má Oclusão Classe II de Angle/diagnóstico , Estética Dentária , Má Oclusão Classe II de Angle/terapia , Aparelhos Ortodônticos Removíveis
19.
Rev. dent. press ortodon. ortopedi. facial ; 9(3): 91-109, maio-jun. 2004. tab, graf
Artigo em Português | LILACS, BBO | ID: lil-404285

RESUMO

O presente estudo foi realizado com o propósito de avaliar respostas cefalométricas ao tratamento com aparelho extrabucal de Kloehn associado ao aparelho fixo edgewise convencional. Telerradiografias iniciais (T1) e finais (T2) de dois grupos de trinta pacientes tratados com estes aparelhos foram selecionadas e definidas pelo índice cefalométrico de Jarabak para determinação do padrão esquelético craniofacial. Os grupos foram denominados favorável (hipodivergente) e desfavorável (hiperdivergente). A idade média, no início do tratamento, foi de 11,03 anos e final de 14,72 com o tempo médio de tratamento de 3,6 anos para o grupo favorável. No grupo desfavorável a idade inicial foi de 11,51 anos e final de 15,17 anos com tempo médio de tratamento de 3,4 anos. Foi utilizado um sistema de análise de resposta de tratamento em coordenadas X e Y representativos dos movimentos dentários e das bases ósseas decompondo-os em seus vetores horizontais e verticais. Os resultados e respostas do tratamento foram analisados e comparados entre os grupos favorável e desfavorável utilizando o teste t-Student. Os resultados mostraram não haver diferenças estatisticamente significantes na resposta cefalométrica no tratamento com o aparelho extrabucal de Kloehn associados ao aparelho fixo edgewise quanto aos padrões faciais favorável ou desfavorável. O tratamento promoveu uma restrição do deslocamento anterior maxilar e um menor deslocamento anterior mandibular. Quanto à movimentação dentária maxilar, houve uma restrição do movimento mesial e extrusivo dos molares superiores no grupo favorável, enquanto que o movimento dos dentes inferiores foi mínimo no sentido anterior e vertical


Assuntos
Humanos , Criança , Cefalometria , Aparelhos de Tração Extrabucal , Má Oclusão Classe II de Angle
20.
J. bras. ortodon. ortop. facial ; 6(33): 183-187, maio-jun. 2001. ilus
Artigo em Português | LILACS, BBO | ID: lil-306996

RESUMO

Mordidas cruzadas anteriores säo maloclusöes observadas com relativa freqüência durante o período da dentadura decídua e início da dentadura mista. O número de dentes envolvidos, inclinaçäo axial dos incisivos, envolvimento ou näo das bases ósseas maxilares e idade do paciente, säo indicadores do tipo de tratamento a ser instituído. O objetivo deste artigo é relatar o caso clínico de uma paciente de três anos de idade, portadora de mordida cruzada anterior, que foi tratadas com o uso do aparelho progênico modificado


Assuntos
Humanos , Feminino , Pré-Escolar , Má Oclusão/terapia , Aparelhos Ortodônticos , Dente Decíduo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA